banner

Video Editing Storage

Show Schedule

ITpro Expo &
Security Solution
Oct 18-20, 2010

Big Sight, Tokyo, Japan
Hall
Booth No.:

JoomlaGATor!

SS-4552E

The Arena SS-4552E features an AMCC PPC440SP CPU, dual 3Gb SAS channels, twelve SAS drive bays, and fully modularized componentsand hot swappable power supplies and fans to reduce the amount of operating downtime for maintenance. The subsystem supports RAID 6 to further increase data integrity and reliability. Also featured in the SS-4552E is an expansion port to attach our JBOD expansion.

* Specifications are subject to change by Arena without notice

Photo

Click to enlarge photo!



Ideal Applications
- Enterprise Storage
- Disk to Disk Backup
- Performance Driven HD
- Video Streaming Applications
- Security and Surveillance
- Regulation Compliance Storage
- Disaster Recovery Storage
- Audio and Video Editing
- VOD on Education or Entertainment
- Fixed Content Archiving



Specifications


Host Interface: Mini SAS
Data Transfer Rate: Up to 12Gb/s per port
Number of Host Channels: 2
JBOD Expansion: Yes (supports up to 120 disks (include local chassis))

Controller CPU: AMCC PPC440SP
Cache Memory: 1G - 4GB DDR II SDRAM
Disk Interface: SAS (SATA II compatible)
Number of Disk Channels: 12
Hot Swap Disk Tray: 3.5" hot-swappable tray
Hot Swap Fan: 2 x Turbo Fan
Hot Swap Power supplies: 350 W x 2 Redundant
AC Input Voltage: 100 to 240V (+/- 10%), 47 to 63 Hz
RAID Levels: JBOD, 0, 1, 3, 5, 6, 10, 30, 50, 60, NRAID
RAID Features:
-Online RAID level and stripe size migration 
-Online disk group expansion
-Online disk group defragmentation for free space consolidation
-Online volume management, support striping and concatenating
-Online LUN capacity expansion and shrink
-Online manual or periodic disk scrubbing with parity check and rebuild
-Disk health monitoring and self tests by S.M.A.R.T. technology
-Online drive traveling and array roaming
-Independent LUN caching policies with dynamic optimization algorithms
-Support A/V streaming performance profile with fast read response

Advanced Data Reliability Assurance: SMARTCor. Functions (DST, DS, DC)

Front Panel LCD and Buttons: Easy access for configuration and status report.
RS-232 Terminal: User Friendly interface for configuration and status report
Web browser GUI: Embedded CGI-based GUI management interface
Event Notification: Built-in buzzer, e-mail, SNMP trap
Management AP: PathGuard, RAIDGuard Central, Windows VDS

Humidity: 20% to 80% non-condensing
Operating Temp: 5 °C to 40 °C
Non-Operating Temp: -25 °C to 60 °C
Safety Regulatory: UL, CUL, CB
EMC Standard: FCC, CE, C-Tick, BSMI

Physical Dimensions: 485 (W) x 565 (D) x 88 (H) mm
Physical Weight: 19 Kgs (without drives)
Packed Dimensions: 610 (W) x 790 (D) x 430 (H) mm
Packed Weight: 28 Kgs (without drives)

Key Features


Click a feature for more info!
The JanusRAID2 series features a new innovative array structure that hierarchically organizes storage objects. With this structure, physical drives are combined into Disk Groups (DG). Disk Groups are subdivided into Logical Disks (LD) where arrays are created. Lastly, Logical Disk can be combined or stripped together to form Volumes. Either volumes or LD can be pointed to a LUN which are then presented to the host computer.
New physical disks can be added by expansion of a Disk Group (DG) while the unit remains online. During the process of expanding Disk Groups, defragmentation can be selected to move unused capacity to the ending LBA of a Disk Group. Defragmentation can also be selected at anytime there is unused storage space residing between Logical Disks.
Logical Disk (LD) Online Expansion can increase the capacity of an online LUN, instead of having to create a separate partition for unused capacity or capacity gained from Disk Group Expansion; now your storage can dynamically grow as your demands grow. In the event of overestimating requirements for Logical Disk capacity, shrinking can be used reduce the allocated storage of a Logical Disk.
This newly added feature provides users the option to attach a JBOD unit to expand the capacity of their Arena Maxtronic storage solution. By allowing the SA-6651E to control the RAID-less JBOD units helps reduce the total cost of ownership.
The JanusRAID2 series now provides an Array Recovery Utility (ARU) that can aid a user in the event of multiple drive failures corrupting the RAID array of a Logical Disk and/or volumes. The ARU enables users to recover lost disk members of a Disk Group, and will automatically recover Logical Disks and Volumes.
With the new JanusRAID2 storage structure, local and global spares can be configured. Local spares will belong to specific Disk Groups and will only replace faulty drives in a specific Disk Group. Meanwhile, Global Spares will replace faulty disk in any available Disk Group.
A simplified feature of Disk Scrubbing (DS), Regenerate Parity will regenerate the parity of a Logical Disk(s) in a Disk Group without a parity check.
Dual Flash ROM per controller gives higher RAID system availability and reliability during firmware upgrading or in the event of a single ROM failure.
Embedded CGI-based GUI (graphic user interface) management interface can be accessed through a web browser. The GUI allows users to easily setup RAID arrays, lun mapping, etc. and also provides remote monitoring of drive health, fan, and power supplies.
RAID 6 improves over the industry standard RAID 5 by adding another parity disk which gives greater reliability and data protection.
Before the release of this function, users of RAID systems were forced to test suspected bad hard drives in a host computer individually using a drive manufacturer’s utility. This function tests the health of hard drives with them installed in the RAID unit. DST performs write tests, servo analysis, and read scan tests; the test results are then displayed on the LCD and hyper terminal output. This can aid the user in deciding whether or not to replace a suspected failing hard drive. We highly recommend running this test before initializing a RAID set to ensure a healthy RAID solution.
With today’s RAID subsystems being capable of storing multiple terabytes, it is becoming increasingly difficult to manage and maintain that large amount of data. To aid a user in maintaining their data’s health, Arena-MaxTronic has released their newest firmware function Disk Scrubbing. The data and/or parity stored on hard drives can sometimes become corrupted; this data can also reside in areas that are not accessed for long periods of time. DS will use idle time to test the disks, and if a sector is found to be corrupted, the data will be regenerated from other RAID member disks and will be written to an uncorrupted sector. The purpose of DS is to prevent the possibility of having multiple corrupted sectors in a single stripe, which is one of the main causes of data loss.
Hard drives are the most likely component to fail in a RAID array, and almost impossible to predict when the failure will occur. When a failure does occur the RAID unit will have to regenerate data from the non-failed hard drives to rebuild a new drive, and the RAID array will be in degraded mode. Having a unit in degraded mode is a very cautious time because if a second hard drive was to fail the RAID is destroyed and data is lost. This is where Disk Cloning can aide a user. With the help of the hard drives built in S.M.A.R.T. function, DC can determine when to begin cloning a bad drive to a hot spare. Upon completion of cloning, the new cloned disk can take the position of the failing disk or can stand-by until the original disk fails, then take the failed disks position. Disk cloning is to prevent a rebuild from ever occurring and having the unit in degraded mode.
Two firmware options are available to surpass the 2 terabyte limitation; 16byte CDB and variable sector size. With either of these functions enabled, users are able to create slices and map LUNs greater than 2TB to their respective host channels. See support documentation for compatibility or contact technical support for more information.
Initialization occurs during creation of a RAID array by zeroing out / formatting drives. By default the initialization process occurs with the unit offline, and inaccessible. With background initialization, the RAID array can be accessed during the initialization process so that the unit can be setup without having to wait several hours to complete initialization.
An optional BBU can be included in the RAID system to ensure data integrity in the event of a power outage. The BBU, or battery backup unit, will provide power to the on-board cache of the RAID controller in the event of a power outage. This will allow any data that is still stored on the cache to be saved until power is restored. Once power is restored, the RAID controller will flush the cache to drives.



Downloads

Firmware: Download

User Manual Download: Hardware | Software

SS-4552E Brochure

GUI Preview

The JanusRAID2 Graphic User Interface, or GUI, is a CGI-based RAID subsystem management tool which is operated using a web browser. It enables users to quickly and easily setup and configure the array, monitor status and performance, and enable event notification via SNMP and SMTP. The new GUI has many new functions and features that can greatly enhance your experience with Arena Maxtronics RAID products.

RAID Management

 

• View health of hard drives
• Setup Disk Groups, Logical Disks, and Volumes
• Provision Storage

 

Event Management

 

• View event log in real time.
• Configure SNMP, or SMTP event notification
• Setup UPS monitoring and control

 

Performance Management

 

• View performance for individual hard disks, cache,
luns, and storage ports

 

Maintenance

 

• Online expansion of Disk Groups, and Logical Disks
• Clone Hard drives
• Run Disk Scrubbing, and Disk Self Test
• Regenerate Parity of RAID arrays
• Perform Array Roaming or Recovery
• Tasks can be scheduled for a later time

 

System Management

 

• Restore settings to Factory Defaults
• Save and Restore configurations to file, or member disks
• Setup Network connection, time, and security settings
• View System Information
• Update Firmware

 

 

Spare Parts

SS-4552E Accessories and Spare Parts.

Photo Part No. Part Name Qty
49-00003-5002 Controller Module, for SS-4552E 1 set
46-93000-5010-110 SAS-to-SAS Controller Board, for 2U 12Bay 1 piece

46-89230-5000-120 LCD Button Board 1 piece
46-58039-5000-210 IO Board 1 piece
46-89300-5010-120 Back Plane, for 2U12bay SAS series 1 piece
51-30000-5004 Power Supply, 350W 1 piece
42-01620-5013 HDD Tray 1 piece
42-00720-5001 Fan Set, for 2U series 1 set
51-60000-5001 Rail 1 piece
42-00000-5022 Extender 1 piece
42-36000-5004 Key, 2pcs 1 set
43-00003-5080 Power Cable-US, L=180cm 1 piece
43-00003-5090 Power Cable-EU, L=180cm 1 piece
43-00003-5100 Power Cable-AUS, L=180cm 1 piece
43-00003-5110 Power Cable-PSE, L=180cm 1 piece
43-00003-5120 Power Cable-UK, L=180cm 1 piece
42-24632-5001 Screw Pack #6/325mm, 30pcs 1 pack
42-24545-5001 Screw Pack #M5, 2pcs 1 pack
42-24645-5001 Screw Pack #M6, 2pcs 1 pack
42-24045-5001 Screw Pack #10-32, 2pcs 1 pack
43-00001-5001 RS232 Cable, L=180cm 1 piece
43-00026-5010 External SAS cable, L=100cm 1 piece
49-00003-5009-001 BBM Module, 3U16bay/2U12bay 1 piece